直流減速電機電阻不合格的原因
一般情況下,直流減速電機電(dian)(dian)阻不合(he)(he)格(ge)(ge)也不是經常(chang)發生,但當直流減速電(dian)(dian)機遇到電(dian)(dian)阻不合(he)(he)格(ge)(ge)這(zhe)一(yi)故障(zhang)時,我們切不可亂了陣腳,并要仔細(xi)分(fen)析其發生的原因(yin)采取(qu)補救(jiu)措(cuo)施(shi)。下面就(jiu)由兆威機電(dian)(dian)的工程師們為大家簡要概(gai)括一(yi)下原因(yin):
1、繞組(zu)故(gu)(gu)障(zhang)方面:繞組(zu)有匝間(jian)短路故(gu)(gu)障(zhang);繞組(zu)與機(ji)殼有兩(liang)處(chu)或(huo)兩(liang)處(chu)以上接觸(chu),產生接地故(gu)(gu)障(zhang)。
2、繞(rao)組連(lian)接(jie)方面:組元(yuan)件(jian)連(lian)接(jie)不(bu)正確(que);輪減速電機連(lian)接(jie)線,引(yin)線長度(du)或截面積(ji)不(bu)符要求。檢查繞(rao)組元(yuan)件(jian)連(lian)接(jie)規律,將連(lian)接(jie)錯誤(wu)的元(yuan)件(jian)糾正過來。
3、導(dao)線(xian)(xian)斷(duan)裂方面:聯(lian)導(dao)線(xian)(xian)悍接處斷(duan)裂;圈引線(xian)(xian)或(huo)(huo)彎折處導(dao)線(xian)(xian)斷(duan)裂;繞導(dao)線(xian)(xian)或(huo)(huo)并(bing)聯(lian)支路中導(dao)線(xian)(xian)有斷(duan)裂處。用儀表檢查(cha),輕輕搖動導(dao)線(xian)(xian),儀表指針會隨(sui)著擺動,導(dao)線(xian)(xian)斷(duan)裂處用試燈(deng)或(huo)(huo)絕緣電(dian)阻表檢查(cha)比較方便,檢查(cha)出來后重新焊(han)接好。
4、電(dian)磁線(xian)(xian)規格方面:磁線(xian)(xian)粗細不(bu)均,一(yi)段合格,某一(yi)段不(bu)合格。
5、重繞線(xian)(xian)圈工藝方面:減速電機線(xian)(xian)圈尺寸大小不(bu)(bu)一致,線(xian)(xian)圈匝數(shu)不(bu)(bu)對;線(xian)(xian)時(shi)拉力不(bu)(bu)均。
以上就是為大家介紹的關(guan)于直流減速電機的知識了,如果您想了解更多(duo),請關(guan)注兆威機電,更多(duo)精彩與(yu)您分(fen)享!